The position transducer is integrated into the cylinder. For this purpose, the measuring rod is located within the hollow-bored piston rod, and the electronics tube is surrounded by a protection tube.
We recommend sending hydraulic cylinders with inductive position transducers to Hänchen for disassembly. After assembly, calibration of the position transducer is required.
In hydraulic cylinders with an inductive position transducer, the immersion anchor of the position transducer is fixed in the hollow-bored piston rod via a clamping piece and a clamping sleeve.
The Hänchen assembly tool for inductive position transducers with immersed anchor mounting can be found as tools in our product configurator HÄKO.
|
|
|
|
The version with a closed protection tube offers the possibility of mounting further accessories, such as a spherical rod eye. If available, accessories must be dismantled before dismantling the inductive position transducer.
|
|
Inside the protection tube, the position transducer is secured with a synthetic retaining flange. The synthetic retaining flange is screwed to a mounting flange. The position transducer, synthetic retaining flange, and mounting flange can be removed as a single unit.
|
|