Mounting plates are used for the direct mounting of control valves on the hydraulic cylinder.
The selection of the appropriate mounting surface depends on the flow rate and the selection of the control valve.
| Mounting surface | ISO | DIN | Qmax | Example |
![]() |
ISO 4401-03 | DIN 24340-A6 | 40 l/min | NG 6 |
![]() |
ISO 4401-05 | DIN 24340-A10 | 100 l/min | NG 10 |
![]() |
ISO 4401-05 with T2 |
DIN 24340-A10 with T2 |
160 l/min | NG 10 |
![]() |
ISO 10372-04 | Moog 76 | 63 l/min | Moog 76 |
![]() |
ISO 10372-06 | - | 250 l/min | Moog 72 |
![]() |
ISO 10372-06 | - | 250 l/min | Moog 791 |