Each hydraulic cylinder is tested at the factory:
Test pressure = 1.5 x max. working pressure.
Applied standards
DIN ISO 6022 (mounting dimensions)
ISO 8132 (accessories)
This series is not available in the HäKo, but can be requested from Hänchen.
The working pressure specified in the parts list can be used statically and dynamically for the respective mounting type without restriction. However, the required safety in your plant and the load caused by the dynamic movement must be taken into account.
When using other sealing systems such as Servofloat®, the installation length is extended accordingly and may deviate from the standard dimension.